Blog

Keep up to date with the latest news

Latest Process Control And Instrumentation MCQs – New Chemical Engineering MCQs

Latest Process Control And Instrumentation MCQs – New Chemical Engineering MCQs

This post is comprising of latest ” Process Control And Instrumentation MCQs – Latest Competitive Chemical Engineering MCQs “. Here you’ll get latest chemical engineering mcqs for written test, interview with answers. If you want to improve your knowledge regarding chemical engineering then read these mcqs of Design of Steel Structures.

Latest Chemical Engineering MCQs

By practicing these MCQs of Chemical Process Control And Instrumentation MCQs – Latest Competitive Chemical Engineering MCQs , an individual for exams performs better than before. This post comprising of mechanical engineering objective questions and answers related to Process Control And Instrumentation Mcqs “. As wise people believe “Perfect Practice make a Man Perfect”. It is therefore practice these mcqs of mechanical engineering to approach the success. Tab this page to check “Chemical Process Control And Instrumentation Mcqs” for the preparation of competitive mcqs, FPSC mcqs, PPSC mcqs, SPSC mcqs, KPPSC mcqs, AJKPSC mcqs, BPSC mcqs, NTS mcqs, PTS mcqs, OTS mcqs, Atomic Energy mcqs, Pak Army mcqs, Pak Navy mcqs, CTS mcqs, ETEA mcqs and others.

Latest Process Control And Instrumentation Mcqs

The most occurred mcqs of Process Control And Instrumentation in past papers. Past papers of Mcqs. Past papers of Process Control And Instrumentation Mcqs . Mcqs are the necessary part of any competitive / job related exams. The Mcqs having specific numbers in any written test. It is therefore everyone have to learn / remember the related Process Control And Instrumentation Mcqs. The Important series of Process Control And Instrumentation Mcqs are given below:

Which of the following relates the absorption & evolution of heat at the junctions of a thermocouple to the current flow in the circuit ?

A. Joule heating effect
B. Peltier effect
C. Seebeck effect
D. Thomson effect

Small furnace draught is accurately measured by an inclined tube manometer, in which the manometric liquid used most commonly is __________________?

A. Carbon tetrachloride
B. Water
C. Paraffin
D. Ethylene glycol

Thermodynamics Mcqs

______________ is undesirable in thermocouples used in industries ?

A. Linear relation of emf to temperature
B. Oxidation resistance
C. Corrosion resistance
D. Non-linear relation of emf to temperature

Which is the most suitable instrument for measuring pressure below 3 microns ?

A. Alphatron
B. Mcleod gauge
C. Ionisation gauge
D. Bourdon gauge

A magnetic flowmeter is_________________?

A. Based on the linear relationship between the fluid flow rate and the induced voltage
B. Capable of measuring the flow rate of slurries and electrolytes
C. Based on the principle of Faraday’s law
D. All A., B. and C.

Which of the following flow-metering instruments is an areameter ?

A. Pitot tube
B. Rotameter
C. Venturimeter
D. Hot wire anemometer

Which of the following controllers has maximum offset ?

A. P-controller
B. P-D controller
C. P-I controller
D. P-I-D controller

Working principle of radiation pyrometer is based on the __________________?

A. Kirchoff’s law
B. Wien’s law
C. Stefan Boltzmann law
D. Seebeck effect

Presence of a small amount of water in the organic systems can be determined by the _____________ method?

A. Polarimetry
B. Electrical conductivity
C. Emission spectroscopy
D. Dielectric constant end loss factor

The calibration data of a thermocouple with its cold junction at 0°C are given below. The hot junction of the thermocouple is placed in a bath at 80°C, while its cold junction is at 20°C. What is the emf of thermocouple ?

A. 0.80 mv
B. 3.26 mv
C. 2.46 mv
D. 2.43 mv

The second order system with the transfer function 4/(s2 + 2s + 4) has a damping ratio of ___________________?

A. 1.0
B. 0.5
C. 2.0
D. 4.0

A mercury thermometer cannot be used to measure the temperature below the freezing point of mercury, which is _____________ °C?

A. -38.9
B. -60.9
C. -11.9
D. -80.9

_______________ thermometer cannot measure sub-zero (< 0° C) temperature ?

A. Vapor pressure
B. Bimetallic
C. Mercury in glass
D. Resistance

Process Control And Instrumentation Mcqs

The function of a transducer is to _______________ ?

A. Amplify the input signal
B. Modify the input signal
C. Convert the primary signal into a more useful quantity, usually an electric impulse
D. Codify/decodify the input signal

Routh stability method uses ______________ loop transfer function?

A. Open
B. Closed
C. Either of the above
D. Neither of the above

Magnetic flowmeters are generally not used for the velocity/flow measurement of hydrocarbons due to their ?

A. High viscosity index
B. Low electrical conductivity
C. Low thermal conductivity
D. Low flash point

Instrumentation in a plant offers the advantage of_______________?

A. Greater safety of operation
B. Greater operation economy
C. Better quality of product
D. All A., B. and C.

Typical specifications for design stipulates the gain margin and phase margin to be respectively__________________?

A. > 1.7 and > 30°
B. < 1.7 and 1.7 and < 30°
C. 30°

Which of the following is an undesirable dynamic characteristic of an instrument ?

A. Dead zone
B. Reproducibility
C. Time lag
D. Static error

Phase lag of the frequency response of a second order system to a sinusoidal forcing function______________?

A. Is 90° at the most
B. Is 30°
C. Approaches 180° asymptotically
D. Is 120°

Latest Process Control And Instrumentation MCQs – New Chemical Engineering MCQs